11 Heavy Truck Chargers
YINMA Equipment and Installation Guidance for a Yueqing Charging Station
YINMA supplied 11 heavy truck chargers and guided the installation. Cable laying, foundations and site civil works were carried out by the contractor.

Heavy Truck Charging Is Not Passenger Car Charging
The Yueqing site installs 11 heavy truck chargers with a new cable route. High power, concentrated charging windows and long vehicles make the electrical and site design more demanding.
Heavy truck batteries are large, single-connector power is high, and charging windows are concentrated. Eleven chargers on one site create a load that is very different from a passenger car park: cable current, voltage drop, protection selectivity and heat all need to be checked together.
The project installs 11 heavy truck chargers with new cable laying. YINMA supplied the charging equipment and guided installation; cable laying, foundations, canopy and other civil works were carried out by the contractor.
Who Did What
YINMA supplied the chargers and guided equipment installation; the contractor carried out cable laying and civil works.
| Scope | YINMA Electric | Contractor |
|---|---|---|
| Equipment | 11 heavy truck chargers | — |
| Installation | Guidance: foundation interface, cable entry, earthing, protection, commissioning | Foundations, cable laying, canopy, civil works |
| Commissioning | Charger settings, communication and charging test support | Power supply and cable termination |
YINMA's role is not to replace the construction crew. It is to make sure the 11 chargers are installed correctly, connected correctly and commissioned before the station opens.
Six Checks for an 11-Charger Site
Points checked during installation and before energization.
Load Split and Voltage Drop
Divide the 11 chargers into circuits and check voltage drop on the longest run. A cable that is adequate on paper can still fail at the last charger.
Cable Route and Bending Radius
Check trench or duct route, bending radius and pulling tension. Heavy truck chargers use large cables; damage during pulling is expensive to fix.
Foundation and Anti-Collision
The charger foundation must be level and strong enough, with bollards or barriers protecting the cabinet from truck movement.
Earthing, Leakage and E-Stop
Verify earthing, residual current protection and emergency stop circuits for each charger group.
Group Control and Metering
Check communication wiring, group control settings and metering points before the first charging session.
Pre-Energization Checks
Insulation, phase sequence, protection settings and a real charging test on each unit.
From Foundations to the First Charge
Photos follow the installation sequence: cabinet placement, cable route, termination and charging modules.






What African Mining and Logistics Fleets Can Reuse
Heavy truck electrification is moving from pilots to fleets in African mining, ports and logistics corridors.
1. Concentrated High-Power Load
Eleven chargers create a concentrated load. Grid capacity, transformer sizing and cable sections must be checked before the first truck arrives.
2. Heat, Dust and Continuous Use
In African mining and port sites, chargers run in high ambient temperature and dust. Ventilation, filtering and maintenance access need more margin.
3. Phased Fleet Rollout
Start with a few trucks and add chargers later. The cable route and switchboard should be designed for the final fleet, not just the first phase.
For African fleet operators, the charging station is a power project: cable route, protection, earthing and load management matter as much as the chargers themselves.
Heavy Truck Charging Equipment and Guidance
YINMA supports charging stations for heavy trucks, logistics fleets and mining operations.
- Heavy truck charger supply, single or multi-unit projects;
- Load split and cable-route review for multi-charger sites;
- Installation guidance for foundations, cable entry and earthing;
- Commissioning support and charging tests.
For charger options, contact YINMA. For station design, see the selection guide. To discuss an 11-charger site, contact YINMA. For a two-substation charging project, see the Taizhou 2×1000 kVA case.
Common Questions
Q: How large a transformer does an 11-charger site need?
A: It depends on charger power, simultaneity factor and charging strategy. Do not add 11 units at full load; calculate the actual demand.
Q: How do you control voltage drop?
A: Shorten the route, increase cable section and split circuits. This must be checked at design stage, not after installation.
Q: Does YINMA lay the cables?
A: No. YINMA supplies the chargers and guides installation; cable laying and civil works are carried out by the contractor.
Heavy Truck Charging Needs a Power Design
YINMA Chargers for Fleet and Mining Sites
From a single heavy truck charger to an 11-unit station, YINMA supports fleet, port and mining charging projects with equipment and installation guidance.